1 Thermal Performance Decline & Fouling

Fouling is the accumulation of unwanted materials (scaling, biological matter, chemical deposits) on heat transfer surfaces, which insulates the plates or tubes and decreases thermal efficiency.

Probable Cause Diagnostic Indicator Recommended Action
Scale formation (carbonate/silica) High approach temp, increased pressure drop Run chemical wash CIP with mild acidic solution
Particulate sedimentation or mud Gradual drop in heat transfer coefficient Flush system, increase fluid velocity, check filters
Bio-growth or algae fouling Usually occurs on cooling tower/water loops Inject biocides or chlorinate cooling water supply

2 Excessive Pressure Drop & Flow Restraints

When the pressure drop across the exchanger exceeds design limits, pumps will work harder, utility costs rise, and flow rates will decrease below processing requirements.

Probable Cause Diagnostic Indicator Recommended Action
Solid particles blocking channels Sudden spike in pressure drop, flow blockage Backflush the system or open unit to remove debris
Excessive flow rate (over-pumping) Flow rate is higher than thermal design capacity Install flow orifice or adjust pump speed / VFD
Incorrect plate assembly configuration Occurs after manual reassembly of GPHE plates Verify plate sequence/alignment matches drawing

3 Tube Vibration & Mechanical Noise

High fluid velocities can cause mechanical vibration in shell & tube heat exchanger tubes. If untreated, vibration leads to wear at baffle contact points and tube failure.

Probable Cause Diagnostic Indicator Recommended Action
Acoustical vibration in shell High-pitched noise or hum, tube rubbing Install derating orifice or acoustic baffles
Fluid-elastic instability (vibe) Tubes hitting each other, leaks at tube sheets Insert tube stakes or reduce shell-side flow velocity
Baffle wear / tube erosion Leaks detected on pressure tests at shell joints Plug damaged tubes, plan support baffle upgrades
Direct Support

Get a Custom Drawing & Quote

Our engineering team in Ghaziabad is ready to run thermal design calculations and supply standard or custom configurations for your system.

Request Direct WhatsApp Quote
Call / WhatsApp +91-9818175924 +91-9350316067
Engineering Office +91-9871082459 +91-7011069994
Manufacturing Plant 18, Anand Industrial Estate, Mohan Nagar, Ghaziabad, Uttar Pradesh 201007, India
Visit PAL ENGINEERS Enquire & Buy